Health Canada Updates List of Recognized Standards for Medical Devices! Simplified Document Review Available for Certain Products
Views:140
Time:2026-11-11 14:27:30


Health Canada has updated its List of Recognized Standards for Medical Devices. The revised version takes effect on November 2, 2026. This list serves as the core technical reference for domestic enterprises applying for Canadian MDL medical device licences, directly affecting registration dossier preparation, test item selection and declaration of conformity.



原
文
链
接


https://www.canada.ca/en/health-canada/services/drugs-health-products/medical-devices/standards/list-recognized.html

一、What is Health Canada’s List of Recognized Standards?



Under Canada’s Medical Devices Regulations, the legislation only outlines general principles for safety and effectiveness. If a manufacturer’s product complies with a recognized standard listed here and issues a Declaration of Conformity, submission of raw test reports for the corresponding scope may be waived in most cases, greatly reducing the burden of registration review.


Important Notes:
  • The list generally no longer marks standard year versions. Some standards specify that certain clauses/annexes are not recognized; full recognition of the entire standard is not guaranteed.
  • Compliance with a recognized standard does not automatically grant market approval. Full assessment of product risk, clinical evidence, labelling and all other regulatory requirements is still mandatory.
  • The list is subject to ongoing additions, updates and removals. Once an old standard is removed, it may no longer be referenced for new registrations.
二、Three Major Changes in This Update: Added | Updated | Removed



(一)Newly Added Key Standards
Multiple ASTM, EN, IEC, ISO and CLSI standards are included in this round, covering MRI magnetic resonance compatibility, medical masks, medical electrical equipment for emergency care, surgical robots, breathing circuit biocompatibility, orthopaedic implants, contact lens care products and IVD specimen evaluation, among other high-demand areas.

Representative Newly Added Standards:
  • ASTM suite for MRI applications: F2052, F2119, F2182, F2213, F2503, for assessment of displacement, torque, RF heating, artefact and marking requirements for medical devices in MRI environments; plus ISO TS 10974 for MRI safety assessment of active implantable devices.
  • ASTM F2100: Standard specification for material performance of medical face masks (mask material standard, not MRI-related)
  • EN 14683: Medical face masks
  • IEC 60601-1-12: Collateral standard for medical electrical equipment used in emergency medical services environments
  • IEC 80601-2-77: Particular safety standard for robot-assisted surgical equipment
  • ISO 18562-1~4: Full set of 4 parts on biocompatibility of breathing gas pathways
  • ISO 21535 / 21536: Specific requirements for hip and knee joint replacement implants
  • CLSI EP35: Evaluation of specimen type equivalence for medical laboratory testing

Note:The “added” label on the list does not mean amendments to the text of Canada’s Medical Devices Regulations. It means Health Canada has newly accepted an international or industry standard as supporting compliance evidence. Manufacturers may voluntarily adopt these standards to support registration applications and streamline document review; there is no mandatory requirement to upgrade products immediately to meet the new standards.

(二)Updated Standards (with Special Restriction Clauses)
  • CLSI EP25 (Evaluation of stability for in vitro diagnostic reagents): 2nd edition, 2023. Clause 7.1.2.3 is not recognized.
  • IEC 60601-2-24 (Infusion pumps): Official guidance to reference AAMI TIR101 for infusion performance testing, and labelling must align with evidence requirements for Class II/III infusion pumps outlined in Canada’s 2018 notice.
  • ISO 10993-1: 6th edition, 2025: If products fall under clause 6.5.11.2, manufacturers may need supplementary testing beyond the scope of this clause. Compliance with the standard text alone cannot be used to prove fulfilment of Canadian requirements.

(三)Removed Standards (Do NOT cite for new registrations)
A number of legacy standards have been deleted from the list, typical examples below:
  • ASTM F2083: Knee joint prostheses
  • Legacy IEC 60601-2-26 (Electrocardiographs), IEC 60601-2-49 (Multiparameter patient monitors) (replaced by the 80601 series)
  • Old edition ISO 8359: Safety of oxygen concentrators
  • ISO 17665-1: Legacy subsection on moist heat sterilization (replaced by ISO 17665)
  • CLSI MM12, MM16: Molecular diagnostic guidelines

Reminder: For products already licensed and on the market, refer to change control requirements. Removed standards are prohibited for newly submitted registration applications.
三、15 Categories of Standards Covering All Medical Device Segments



The official list classifies all recognized standards into 15 modules. Manufacturers can quickly locate applicable standards by product category:
  1. Anesthetic and respiratory
  2. Biocompatibility
  3. Cardiovascular
  4. Contraception
  5. Dental
  6. Electromedical (the IEC 60601 family)
  7. General (packaging, gloves, masks, risk management ISO 14971, clinical ISO 14155, etc.)
  8. In vitro diagnostic (IVD) (CLSI, IEC 61010 series)
  9. Manufacturing: Production, cleanroom facilities
  10. Materials: Implant metals, polymers, ceramic raw materials
  11. Neurology: Implantable stimulators, cochlear implants, etc.
  12. Ophthalmology: Intraocular lenses, contact lens care products
  13. Orthopedics: Orthopaedic implants, spine, joints, suture anchors
  14. Radiology: Radiography, ultrasound, CT, DR, dental X-ray
  15. Sterilization
四、Practical Recommendations for Chinese Export Manufacturers



Cross-check the list version before registration:Before submitting any Canadian MDL registration, always open the latest official Health Canada list to verify the recognized status of standards you intend to cite. Carefully read notes for each standard to confirm which clauses are not accepted, avoiding invalid test results after testing is completed.
Track standard replacement relationships:Many legacy IEC 60601-2-XX standards are superseded by the 80601 series and removed from the list. Test and registration documents must switch to the new edition numbers.
Do not rely solely on ISO 10993 for biocompatibility:Certain in vitro alternative method clauses in ISO 10993-10 and ISO 10993-23 are explicitly unrecognized by Health Canada. Safety assessment cannot rely only on these unaccepted in vitro alternatives (e.g. in vitro skin irritation/sensitization tests) to replace animal testing — this is a common pitfall for manufacturers.
Establish an internal standard tracking mechanism:Health Canada revises the list periodically. Compliance teams should review this page regularly and assess impacts on licensed legacy products and new product development and test protocols.
Complete Declaration of Conformity truthfully:nly list standards recognized in the official list. Where certain clauses of a cited standard are not accepted, the declaration and test report must exclude these unrecognized clauses and document alternative approaches adopted.
五、Conclusion



Compliance thresholds for the Canadian market continue to evolve, and the List of Recognized Standards serves as a core roadmap for medical device manufacturers exporting to Canada. We recommend manufacturers follow updates to the list on a regular basis, adjust test protocols and registration dossiers in advance, avoid common pitfalls such as expired standards and unrecognized clauses, and smoothly advance MDL registration.Should you require further information, feel free to contact Wiselink!


Contact Us
Fill Form
Whether you need more information or wish to cooperate with us, we will guide you through every step of the regulatory process. Subscribe to our newsletter for the latest global regulatory updates.